AKCP Smoke Sensor
AKCP Smoke Sensor SK00 - Robust Fire Defense for Vital Infrastructure
The AKCP Smoke Sensor SK00, with its SNMP capabilities, is engineered for early fire detection in high-stakes environments such as server rooms, data centers, manufacturing facilities, and storage areas. A fire can devastate these critical spaces within minutes, leading to severe financial losses and legal ramifications from data loss or regulatory non-compliance.
In mission-critical settings, the SK00 serves as a cornerstone of fire safety, delivering rapid detection to mitigate risks before they escalate. Its advanced photoelectric technology ensures precise identification of smoke, enabling swift responses to prevent catastrophic damage. Integrated with network monitoring systems, it provides continuous oversight and immediate alerts, making it an essential tool for protecting valuable assets and ensuring operational continuity in both local and remote locations.
Fire Hazards in Critical Infrastructure
- Unpredictable sources: Arson, whether negligent or deliberate.
- Equipment failures: Overheating servers or defective power supplies.
- Electrical issues: Lightning strikes or power surges.
- System malfunctions: Overheated cooling or UPS units.
- Wiring problems: Spontaneous combustion from faulty cables.
- Short circuits: Electrical faults triggering fires.
Without redundant systems, businesses face significant downtime costs and potential legal issues from data loss or compliance breaches.
Technical Specifications of the SK00 Smoke Sensor
The SK00 leverages photoelectric detection to meet rigorous safety standards, ensuring reliable performance in demanding environments.
Sensor Features
- Detection Method: Photoelectric smoke sensor.
- Range: Binary detection (Smoke / No smoke).
- Temperature Range: -20°C to 60°C (-4°F to 140°F).
- Alarm Output: 85dB at 3 meters.
- Dimensions: 130mm diameter, 51mm height.
- Power Usage: 290 mW (58mA).
Safety Features
- Test Button: Full functionality check.
- Auto-Reset: Automatic alarm reset after detection.
- Insect-Proof Chamber: Prevents false triggers.
- Low-Profile Design: Optimized for ceiling installation.
- Standards Compliance: Meets UL 217 and BS 5839 pt 6 Grade F.
- Indicators: LED and strobe light for smoke alerts.
Network Integration and Monitoring
The SK00 integrates seamlessly into network systems via an RJ45 port with Cat5/Cat6 cables, connecting to AKCP sensorProbe or securityProbe units. Its unique OID allows direct SNMP querying, ensuring compatibility with platforms like Nagios, HP OpenView, WhatsUp Gold, and OpenNMS for centralized oversight.
Alert and Notification Systems
The user-friendly AKCP web interface enables easy sensor configuration and versatile alert options:
- Email Notifications: Sent to up to 6 recipients simultaneously.
- SMS Alerts: Via third-party gateways.
- SNMP Traps: Forwarded to monitoring systems.
- Fire System Integration: Connects to alarm panels.
A disconnect alarm enhances security by detecting tampering or cable issues, critical for remote or unmanned sites.
Installation and Mounting Options
The SK00 is designed for ceiling mounting to capture rising smoke effectively, with options for direct installation in server cabinets.
- Ceiling Installation: Optimizes smoke detection.
- Cabinet Mounting: Protects critical hardware directly.
- Screw Fixing: Secure attachment with included hardware.
Scalable Monitoring Solutions
The SK00 supports flexible expansion for various infrastructure sizes:
- Daisy Chaining: Up to 10 sensors per port.
- Sensor Spacing: Maximum 30 meters between sensors.
- Dry Contact Inputs: Enables multi-sensor connectivity.
This configuration suits large-scale fire monitoring in data centers, production halls, or multi-site setups.
Safeguarding IT Infrastructure
Fires in critical areas can cripple operations, especially for businesses without redundant systems. The SK00, combined with AKCP’s network-based monitoring, offers robust protection for both local and remote locations.
- Early Warning: Detects fires at initial stages.
- Continuous Oversight: 24/7 sensor surveillance.
- Unified Interface: Manages all sites centrally.
- Alarm Mapping: Pinpoints critical alerts instantly.
- Multi-Channel Alerts: Ensures reliable notifications.
Integration with Security Systems
The SK00 operates alongside existing fire alarm systems, using intelligent sensor ports and dry contact connections for compatibility with AKCP units and conventional panels.
- Parallel Functionality: Works with existing fire systems.
- SNMP Compatibility: Integrates with monitoring platforms.
- Web Management: Centralized configuration.
- Prioritized Alerts: Escalates notifications by severity.
Maintenance and Reliability
Designed for low-maintenance operation, the SK00 ensures long-term reliability with features like:
- Battery Backup: Operates during power outages.
- Self-Diagnostics: Continuous functionality checks.
- Insect Resistance: Maintenance-free chamber.
- Durable Performance: Years of stable operation.
The AKCP Smoke Sensor SK00 combines cutting-edge hardware, seamless network integration, and versatile alerting to deliver top-tier fire protection. Whether for single-site server rooms or expansive critical infrastructures, it safeguards assets and minimizes downtime risks effectively.